From: An adaptive gBOIN design with shrinkage boundaries for phase I dose-finding trials
 | Dose Level |  |  | Dose Level | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Scenario | 1 | 2 | 3 | 4 | 5 | Â | Scenario | 1 | 2 | 3 | 4 | 5 |
1 | 0.20 | 0.25 | 0.35 | 0.45 | 0.50 | Â | 1 | 0.30 | 0.40 | 0.50 | 0.60 | 0.70 |
2 | 0.20 | 0.30 | 0.40 | 0.50 | 0.60 | Â | 2 | 0.30 | 0.45 | 0.60 | 0.70 | 0.80 |
3 | 0.15 | 0.20 | 0.25 | 0.35 | 0.45 | Â | 3 | 0.20 | 0.30 | 0.40 | 0.50 | 0.60 |
4 | 0.15 | 0.20 | 0.30 | 0.45 | 0.55 | Â | 4 | 0.20 | 0.30 | 0.45 | 0.60 | 0.70 |
5 | 0.10 | 0.20 | 0.25 | 0.35 | 0.45 | Â | 5 | 0.15 | 0.30 | 0.40 | 0.50 | 0.60 |
6 | 0.10 | 0.20 | 0.30 | 0.40 | 0.55 | Â | 6 | 0.15 | 0.30 | 0.45 | 0.60 | 0.70 |
7 | 0.08 | 0.15 | 0.20 | 0.25 | 0.35 | Â | 7 | 0.12 | 0.20 | 0.30 | 0.40 | 0.50 |
8 | 0.08 | 0.15 | 0.20 | 0.30 | 0.45 | Â | 8 | 0.12 | 0.20 | 0.30 | 0.45 | 0.60 |
9 | 0.05 | 0.10 | 0.20 | 0.25 | 0.35 | Â | 9 | 0.05 | 0.15 | 0.30 | 0.40 | 0.50 |
10 | 0.05 | 0.10 | 0.20 | 0.30 | 0.45 | Â | 10 | 0.05 | 0.15 | 0.30 | 0.45 | 0.60 |
11 | 0.05 | 0.10 | 0.15 | 0.20 | 0.25 | Â | 11 | 0.05 | 0.12 | 0.20 | 0.30 | 0.40 |
12 | 0.05 | 0.10 | 0.15 | 0.20 | 0.30 | Â | 12 | 0.05 | 0.12 | 0.20 | 0.30 | 0.45 |
13 | 0.02 | 0.06 | 0.10 | 0.20 | 0.25 | Â | 13 | 0.02 | 0.08 | 0.15 | 0.30 | 0.40 |
14 | 0.02 | 0.06 | 0.10 | 0.20 | 0.30 | Â | 14 | 0.02 | 0.08 | 0.15 | 0.30 | 0.45 |
15 | 0.02 | 0.05 | 0.07 | 0.10 | 0.20 | Â | 15 | 0.02 | 0.10 | 0.15 | 0.20 | 0.30 |
16 | 0.01 | 0.06 | 0.10 | 0.15 | 0.20 | Â | 16 | 0.01 | 0.04 | 0.08 | 0.15 | 0.30 |